Cooper Wiring TRAFGF15LA-K-L Self-Test Tamper-Resistant GFCI Duplex Receptacle

Item #: 80035984

Product Info

TRAFGF15LA-K-L
COOPER WIRING

74761 RCPT DPLX AF/GF TR LA 15A 125V
Cooper Wiring TRAFGF15LA-K-L Self-Test Tamper-Resistant GFCI Duplex Receptacle; 1 EA = 1 CD; 3EA/SHELF PACK

Duplex self-test AF/GF with standard-size wallplate, back and side wired. 15A/125V NEMA 5-15R. 2-pole, 3-wire grounding. Wire size number 14 - 10 AWG. Both arc fault protection and ground fault protection. Provides protection from series arcs, parallel arcs, and ground faults. Self-test GFCI technology. Meets and exceeds 10ka short circuit testing and Underwriters Laboratories (UL) UL943 safety standards. Ground termination with back wire clamp. Automatic grounding system eliminates the need for bonding jumper in grounded metal enclosure. Tapered back wire openings handle multiple wire sizes and types for applications up to number 10 AWG solid or stranded wire. Lock-out functionality prevents mis-wired line-load connections and GFCI/AFCI circuitry damage. Visual indicator light provides quick visual reference of a tripped or end of life condition. Tamper resistant (TR) shutters comply with 2014 NEC Article 406.12. Terminal screws backed out and ready to wire. Matching standard size thermoplastic wallplate included.Provides both arc fault protection per UL1699A and ground fault protection per UL943 in one convenient device
  • Provides both arc fault protection per UL1699A and ground fault protection per UL943 in one convenient device
  • Protects from both series and parallel arcs downstream from the outlet branch circuit(OBC) AF/GF receptacle
  • OBC AF/GF receptacles also protect from upstream series arcs
  • Trip indicators make it easy-to diagnose arc and ground faults
  • Device self-tests periodically to ensure proper function of both the ground fault and arc fault protection elements
  • Automatic grounding system eliminates the need for bonding jumper in grounded metal enclosure
  • Provides redundant measure of ground continuity when jumper is used
  • Lock-out functionality prevents miswired line-load connections and GFCI/AFCI circuitry damage
  • Tamper resistant (TR) shutters comply with 2014 NEC Article 406.12
  • ColorLight Almond
    Current Rating15 A
    Dimensions2.81 in L x 2.01 in W x 4.62 in H
    Frequency Rating60 Hz
    IncludesThermoplastic Wallplate
    MaterialPVC/Thermoplastic
    NEMA Configuration5-15R
    Number of Poles2
    Number Of Wires3
    Operating Temperature30 deg C
    Voltage Rating125 V
    Wire Size14 to 10 AWG
    Wiring TypeBack Side